Skip to product information
Y305-EE21 PLC I/O Module

Y305-EE21 PLC I/O Module

Y305-EE21 runs local PLC programs with 14 digital inputs and 14 digital outputs. It also provides 2 analog inputs and 1 analog output for 0–10 V signals.

Digital I/O
14 DI + 14 DO
Analog I/O
2 AI + 1 AO, 0–10 V
Output hardware
Relay or optional NPN transistor
Communication
Up to 2 optional RS485 ports
Power supply
24 VDC nominal
$40.00

Price for the selected configuration.

Output Type
RS485 Ports

Shipping & Tax: Estimate shipping in your cart. Available options and final charges are confirmed at checkout.

Import duties, taxes, customs fees and destination charges are paid by the customer. View Shipping Policy

1-Year Warranty

Expert Technical Support

Overview

Y305-EE21 runs local PLC programs with 14 digital inputs and 14 digital outputs. It also provides 2 analog inputs and 1 analog output for 0–10 V signals.

How it works & selection

The module executes a local PLC program. Optional RS485 ports provide Modbus RTU master/slave or non-protocol RS communication according to the supplied hardware and configuration.

Output and communication

Specify relay or NPN transistor output hardware and the required RS485 port count. Availability depends on the ordered hardware combination. Relay and transistor outputs are different hardware.

Relay outputs cannot generate high-speed pulses. Confirm the required channels and rates for high-speed counting or pulse output against the supplied hardware.

Analog signal

The analog channels use 0–10 V signals. Do not connect a 4–20 mA loop directly or apply an external voltage to the analog output. Confirm input impedance, output load, accuracy and reference limits for the supplied hardware.

Load and installation

Check the output voltage, load category, common-terminal and derating limits for the selected hardware before connecting a load. NPN outputs are for DC loads only.

Y305 is not a safety PLC. Provide independent safety functions and test startup, STOP, power loss and communication recovery with loads isolated.

Technical specifications

Digital I/O14 DI + 14 DO
Analog I/O2 AI + 1 AO, 0–10 V
Output hardwareRelay or optional NPN transistor
CommunicationUp to 2 optional RS485 ports
Power supply24 VDC nominal
I/O and communication
Digital inputs14; dry contact or compatible sinking signal
Digital outputs14; relay or optional NPN transistor
Analog I/O2 AI + 1 AO, 0–10 V
CommunicationUp to two optional RS485 ports; Modbus RTU master/slave or non-protocol RS communication
ProgrammingGX Works2 with an FX3U-style device/instruction model; use the setup specified for the supplied hardware and firmware
RTCStandard; verify clock accuracy, backup and power-loss recovery
Electrical
Power supply24 VDC nominal; confirm permitted range and consumption
Digital input arrangementS/S to +24 V; Xn to 0 V through a dry contact or compatible sinking signal
Relay outputStated ceiling: 5 A at AC 220 V or DC 30 V, subject to load conditions
NPN transistor outputStated ceiling: 3 A; verify output voltage and load ratings; DC loads only
Analog signal2 AI + 1 AO; 0–10 V; 12-bit raw range 0–4095

These output ceilings do not establish continuous per-channel, common-terminal, inductive-load, inrush, or simultaneous-load ratings. RS and ADPRW cannot operate simultaneously.

Dimensions and installation
Enclosure, width × height × depth150 × 99 × 41 mm

Use the drawing for the supplied hardware to verify terminals, mounting and clearances. Confirm environmental, protection, isolation and EMC limits for the installation.

Confirm enclosure dimensions against the supplied NPN hardware.

Package & resources