{"title":"LoRaWAN Products","description":"\u003cp\u003eLoRaWAN gateways and field devices for serial equipment and industrial I\/O. Choose Y501-L for indoor packet forwarding, Y502-L for isolated RS485 and RS232, or Y503-2220-L for digital and analog I\/O. A compatible gateway and Network Server are required for end-device communication.\u003c\/p\u003e","products":[{"product_id":"y501-l-indoor-lorawan-gateway-8-or-16-channels","title":"Y501-L Indoor LoRaWAN Gateway, 8 or 16 Channels","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eY501-L forwards LoRaWAN device traffic to a Network Server through Ethernet or Wi-Fi. Choose 8 or 16 channels, with optional 4G backhaul and local NS\/AS software.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e8 receive \/ 1 transmit or 16 receive \/ 2 transmit radio-channel configurations\u003c\/li\u003e\n\u003cli\u003eSupports LoRaWAN 1.0.2, 1.0.3 and 1.0.4 Class A and Class C end devices\u003c\/li\u003e\n\u003cli\u003e10\/100 Mbps Ethernet and 2.4 GHz Wi-Fi backhaul, with 4G available as an order option\u003c\/li\u003e\n\u003cli\u003eUDP\/GWMP or MQTT packet forwarding to a compatible Network Server, according to deployment mode\u003c\/li\u003e\n\u003cli\u003eLocal Network Server \/ Application Server and RS485 Modbus data access require the corresponding software option\u003c\/li\u003e\n\u003cli\u003eLocal Web configuration and firmware upgrades, with remote management where enabled\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003eLoRaWAN Radio\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupported End Device Versions\u003c\/th\u003e\n\u003ctd\u003eLoRaWAN 1.0.2 \/ 1.0.3 \/ 1.0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupported End Device Classes\u003c\/th\u003e\n\u003ctd\u003eClass A \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency Plans\u003c\/th\u003e\n\u003ctd\u003eCN470 (default), EU433, EU868, AU915, IN865, AS923, RU864, US915; region-specific hardware; specify the AS923 sub-plan when ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChannel Options\u003c\/th\u003e\n\u003ctd\u003e8 RX \/ 1 TX or 16 RX \/ 2 TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuplex\u003c\/th\u003e\n\u003ctd\u003eHalf-duplex or full-duplex hardware options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransmit Power\u003c\/th\u003e\n\u003ctd\u003eUp to 27 dBm; use settings allowed by the regional plan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver Sensitivity\u003c\/th\u003e\n\u003ctd\u003eDown to -140 dBm at SF12, BW125 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpreading Factor\u003c\/th\u003e\n\u003ctd\u003eSF7–SF12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCapacity\u003c\/th\u003e\n\u003ctd\u003eDevice capacity depends on payload size, reporting interval, airtime, interference and regional radio limits. Channel count alone does not determine capacity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eNetwork Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEthernet\u003c\/th\u003e\n\u003ctd\u003e10\/100 Mbps RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWi-Fi\u003c\/th\u003e\n\u003ctd\u003e2.4 GHz; AP, STA or AP+STA, depending on the Wi-Fi variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCellular\u003c\/th\u003e\n\u003ctd\u003eOptional 4G; supported operator bands depend on the cellular module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS485\u003c\/th\u003e\n\u003ctd\u003eStandard A\/B hardware; Modbus RTU data access requires compatible local-service software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB\u003c\/th\u003e\n\u003ctd\u003eMicroUSB USB-TTL debug\/log interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eNetwork Services\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePacket Forwarding\u003c\/th\u003e\n\u003ctd\u003eUDP\/GWMP or MQTT, depending on deployment mode and the Network Server’s supported interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLocal Services\u003c\/th\u003e\n\u003ctd\u003eLocal Network Server \/ Application Server (NS\/AS), available as a software option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModbus Integration\u003c\/th\u003e\n\u003ctd\u003eRS485 Modbus access requires the local-service software option and a matching register map, function codes, byte order and scaling. Packet-forwarding firmware alone does not poll instruments.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePower Supply\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003eDC 9–28 V; typical DC 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Current 8 Channel\u003c\/th\u003e\n\u003ctd\u003e850 mA at DC 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Current 16 Channel\u003c\/th\u003e\n\u003ctd\u003e1.5 A at DC 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAverage Power 8 Channel\u003c\/th\u003e\n\u003ctd\u003e≤3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAverage Power 16 Channel\u003c\/th\u003e\n\u003ctd\u003e≤7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Power 8 Channel\u003c\/th\u003e\n\u003ctd\u003e10.2 W at DC 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Power 16 Channel\u003c\/th\u003e\n\u003ctd\u003e18 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e0–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions 8 Channel\u003c\/th\u003e\n\u003ctd\u003e120.4 × 79.7 × 34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions 16 Channel\u003c\/th\u003e\n\u003ctd\u003e125.5 × 120.4 × 34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight 8 Channel\u003c\/th\u003e\n\u003ctd\u003eApproximately 1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight 16 Channel\u003c\/th\u003e\n\u003ctd\u003eApproximately 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eDIN rail or wall mounting with the matching bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDeployment\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRegional Matching\u003c\/th\u003e\n\u003ctd\u003eMatch gateway, Network Server, and end-device plans and channel groups, including AS923 sub-plan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDownlinks\u003c\/th\u003e\n\u003ctd\u003eClass A receives downlinks after an uplink. Class C provides more receive opportunities. Delivery time depends on airtime, server scheduling and regional radio limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrdering\u003c\/th\u003e\n\u003ctd\u003eSpecify channel count, duplex mode, antennas, backhaul and software options with your order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\n\u003cp\u003eConfirm the regional frequency plan, AS923 sub-plan where applicable, 8- or 16-channel hardware, duplex mode, backhaul, antennas and local NS\/AS software options before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/store.yengear.com\/pages\/contact\"\u003eAsk YenGear to check your configuration\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/docs.yengear.com\/products\/lorawan\/Y501-L-specification.html\"\u003eY501-L Specification Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/docs.yengear.com\/products\/lorawan\/Y501-L-user-manual.html\"\u003eY501-L User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yengear IoT","offers":[{"title":"8 \/ CN470 \/ No","offer_id":67632598941938,"sku":null,"price":228.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ CN470 \/ Yes","offer_id":68090349715698,"sku":null,"price":290.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ AS923 \/ No","offer_id":68090349748466,"sku":null,"price":228.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ AS923 \/ Yes","offer_id":68090349781234,"sku":null,"price":290.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ AU915 \/ No","offer_id":68090349814002,"sku":null,"price":228.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ AU915 \/ Yes","offer_id":68090349846770,"sku":null,"price":290.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ EU433 \/ No","offer_id":68090349879538,"sku":null,"price":228.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ EU433 \/ Yes","offer_id":68090349912306,"sku":null,"price":290.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ EU868 \/ No","offer_id":68090349945074,"sku":null,"price":228.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ EU868 \/ Yes","offer_id":68090349977842,"sku":null,"price":290.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ IN865 \/ No","offer_id":68090350010610,"sku":null,"price":228.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ IN865 \/ Yes","offer_id":68090350043378,"sku":null,"price":290.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ RU864 \/ No","offer_id":68090350076146,"sku":null,"price":228.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ RU864 \/ Yes","offer_id":68090350108914,"sku":null,"price":290.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ US915 \/ No","offer_id":68090350141682,"sku":null,"price":228.0,"currency_code":"USD","in_stock":true},{"title":"8 \/ US915 \/ Yes","offer_id":68090350174450,"sku":null,"price":290.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ CN470 \/ No","offer_id":68090350207218,"sku":null,"price":415.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ CN470 \/ Yes","offer_id":68090350239986,"sku":null,"price":477.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ AS923 \/ No","offer_id":68090350272754,"sku":null,"price":415.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ AS923 \/ Yes","offer_id":68090350305522,"sku":null,"price":477.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ AU915 \/ No","offer_id":68090350338290,"sku":null,"price":415.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ AU915 \/ Yes","offer_id":68090350371058,"sku":null,"price":477.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ EU433 \/ No","offer_id":68090350403826,"sku":null,"price":415.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ EU433 \/ Yes","offer_id":68090350436594,"sku":null,"price":477.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ EU868 \/ No","offer_id":68090350469362,"sku":null,"price":415.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ EU868 \/ Yes","offer_id":68090350502130,"sku":null,"price":477.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ IN865 \/ No","offer_id":68090350534898,"sku":null,"price":415.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ IN865 \/ Yes","offer_id":68090350567666,"sku":null,"price":477.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ RU864 \/ No","offer_id":68090350600434,"sku":null,"price":415.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ RU864 \/ Yes","offer_id":68090350633202,"sku":null,"price":477.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ US915 \/ No","offer_id":68090350665970,"sku":null,"price":415.0,"currency_code":"USD","in_stock":true},{"title":"16 \/ US915 \/ Yes","offer_id":68090350698738,"sku":null,"price":477.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/5563\/3138\/files\/Y501-L-product.png?v=1791080957"},{"product_id":"y502-l-lorawan-serial-dtu-with-isolated-rs485-and-rs232","title":"Y502-L LoRaWAN Serial DTU with Isolated RS485 and RS232","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eY502-L connects meters, PLCs and serial sensors to LoRaWAN through isolated RS485 and RS232. Supports scheduled polling and transparent transport via a compatible gateway.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne isolated RS485 interface and one isolated RS232 interface; no direct DI, DO, AI or AO channels\u003c\/li\u003e\n\u003cli\u003eLoRaWAN 1.0.3 with OTAA\/ABP activation and Class A\/Class C operation\u003c\/li\u003e\n\u003cli\u003eUp to 16 scheduled acquisition scripts plus a heartbeat task, using HEX or ASCII commands\u003c\/li\u003e\n\u003cli\u003eModbus RTU requests, custom serial frames, data-change reports and remote serial commands\u003c\/li\u003e\n\u003cli\u003eTransparent serial data travels in LoRaWAN packets; payload limits and downlink timing affect request\/response operation\u003c\/li\u003e\n\u003cli\u003e9–28 VDC supply, 35 mm DIN-rail mounting and 15 kV ESD protection on both serial interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003eLoRaWAN Radio\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eLoRaWAN 1.0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActivation\u003c\/th\u003e\n\u003ctd\u003eOTAA \/ ABP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDevice Classes\u003c\/th\u003e\n\u003ctd\u003eClass A \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency Plans\u003c\/th\u003e\n\u003ctd\u003eCN470 (reference), EU433, EU868, AU915, IN865, AS923, RU864, US915; region-specific hardware; specify the AS923 sub-plan when ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransmit Power\u003c\/th\u003e\n\u003ctd\u003e-1 to 22 dBm, configurable within regional limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBandwidth\u003c\/th\u003e\n\u003ctd\u003e125 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpreading Factor\u003c\/th\u003e\n\u003ctd\u003eSF7–SF12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver Sensitivity\u003c\/th\u003e\n\u003ctd\u003e-135 dBm at SF12, BW125 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eSerial Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS485\u003c\/th\u003e\n\u003ctd\u003e1 isolated RS485, A+ \/ B−; default 9600 bps, 8-N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS232\u003c\/th\u003e\n\u003ctd\u003e1 isolated 3-wire RS232, TXD \/ RXD \/ GND; default 115200 bps, 8-N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBaud Rates\u003c\/th\u003e\n\u003ctd\u003e2400, 4800, 9600, 19200, 38400, 57600, 115200 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFormat\u003c\/th\u003e\n\u003ctd\u003e8 data bits; 1 or 2 stop bits; none, odd, or even parity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEsd Protection\u003c\/th\u003e\n\u003ctd\u003e15 kV on RS485 and RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDirect Io\u003c\/th\u003e\n\u003ctd\u003eNone: 0 DI, 0 DO, 0 AI, 0 AO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAcquisition\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModes\u003c\/th\u003e\n\u003ctd\u003eTransparent transmission and active acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTasks\u003c\/th\u003e\n\u003ctd\u003eUp to 16 configurable acquisition scripts plus a heartbeat task\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommand Formats\u003c\/th\u003e\n\u003ctd\u003eHEX or ASCII; Modbus RTU or custom serial frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Script Length\u003c\/th\u003e\n\u003ctd\u003e40 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eScript Interval\u003c\/th\u003e\n\u003ctd\u003e10–86,400 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReporting\u003c\/th\u003e\n\u003ctd\u003ePeriodic acquisition, heartbeat, and data-change reporting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRemote Functions\u003c\/th\u003e\n\u003ctd\u003eRemote parameter settings and serial read\/control commands; supported commands depend on the installed firmware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePower Supply\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003eDC 9–28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended Adapter\u003c\/th\u003e\n\u003ctd\u003eDC 12 V \/ 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Current\u003c\/th\u003e\n\u003ctd\u003e0.5 A at DC 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAverage Power\u003c\/th\u003e\n\u003ctd\u003e≤0.5 W in low-duty-cycle operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-50 to 95 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e0–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e87.65 × 36.54 × 59.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApproximately 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAntenna Connector\u003c\/th\u003e\n\u003ctd\u003eSMA female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDeployment\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGateway Compatibility\u003c\/th\u003e\n\u003ctd\u003eY501-L or Y511-L with a matching regional plan and channel group, plus compatible local or remote Network Server settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial Transport\u003c\/th\u003e\n\u003ctd\u003eSerial data travels in LoRaWAN packets. Payload limits, airtime and downlink scheduling affect frame length and request timeouts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDownlinks\u003c\/th\u003e\n\u003ctd\u003eClass A receives downlinks after an uplink. Class C provides more receive opportunities. Delivery time depends on airtime, server scheduling and regional radio limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePayload\u003c\/th\u003e\n\u003ctd\u003ePayload format, FPorts and decoding rules depend on the installed firmware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\n\u003cp\u003eConfirm the regional plan, gateway and Network Server settings, serial protocol and payload format before ordering. This model provides serial interfaces only; it has no direct DI, DO, AI or AO channels.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/store.yengear.com\/pages\/contact\"\u003eAsk YenGear to check your configuration\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/docs.yengear.com\/products\/lorawan\/Y502-L-specification.html\"\u003eY502-L Specification Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/docs.yengear.com\/products\/lorawan\/Y502-L-user-manual.html\"\u003eY502-L User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yengear IoT","offers":[{"title":"CN470","offer_id":67632598974706,"sku":null,"price":47.0,"currency_code":"USD","in_stock":true},{"title":"AS923","offer_id":68090355843314,"sku":null,"price":47.0,"currency_code":"USD","in_stock":true},{"title":"AU915","offer_id":68090355876082,"sku":null,"price":47.0,"currency_code":"USD","in_stock":true},{"title":"EU433","offer_id":68090355908850,"sku":null,"price":47.0,"currency_code":"USD","in_stock":true},{"title":"EU868","offer_id":68090355941618,"sku":null,"price":47.0,"currency_code":"USD","in_stock":true},{"title":"IN865","offer_id":68090355974386,"sku":null,"price":47.0,"currency_code":"USD","in_stock":true},{"title":"RU864","offer_id":68090356007154,"sku":null,"price":47.0,"currency_code":"USD","in_stock":true},{"title":"US915","offer_id":68090356039922,"sku":null,"price":47.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/5563\/3138\/files\/Y502-L-product.png?v=1791080964"},{"product_id":"y503-222-l-lorawan-rtu-2di-2do-2ai-and-rs485","title":"Y503-2220-L LoRaWAN RTU, 2DI\/2DO\/2AI and RS485","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eY503-2220-L connects two digital inputs, two switched voltage outputs, a 0–10 V input, a 4–20 mA input and isolated RS485 to a LoRaWAN gateway and Network Server.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTwo digital inputs share COM and accept dry contacts or powered signals up to 28 VDC, with wiring matched to the sensor\u003c\/li\u003e\n\u003cli\u003eTwo switched voltage outputs follow the RTU supply voltage; they are not dry relay contacts\u003c\/li\u003e\n\u003cli\u003eSeparate fixed-function analog terminals: one 0–10 V AV input and one 4–20 mA AI input, with no analog output\u003c\/li\u003e\n\u003cli\u003eIsolated RS485 supports configured polling and transparent transport, including Modbus RTU data\u003c\/li\u003e\n\u003cli\u003eLoRaWAN 1.0.3, OTAA\/ABP and Class A\/Class C, with periodic, heartbeat and state-change reporting\u003c\/li\u003e\n\u003cli\u003eTimed output, pulse control and local input-to-output rules require compatible firmware and a confirmed output-load rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003eLoRaWAN Radio\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eLoRaWAN 1.0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActivation\u003c\/th\u003e\n\u003ctd\u003eOTAA \/ ABP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDevice Classes\u003c\/th\u003e\n\u003ctd\u003eClass A \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency Plans\u003c\/th\u003e\n\u003ctd\u003eEU433, CN470 (reference), EU868, AU915, US915, AS923; region-specific hardware; specify the AS923 sub-plan when ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransmit Power\u003c\/th\u003e\n\u003ctd\u003e-1 to 22 dBm, subject to regional configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBandwidth\u003c\/th\u003e\n\u003ctd\u003e125 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpreading Factor\u003c\/th\u003e\n\u003ctd\u003eSF7–SF12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver Sensitivity\u003c\/th\u003e\n\u003ctd\u003e-135 dBm at SF12, BW125 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDigital Inputs\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChannels\u003c\/th\u003e\n\u003ctd\u003e2 DI with shared COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSignal Types\u003c\/th\u003e\n\u003ctd\u003eDry contact or powered contact; NPN\/PNP wiring depends on COM connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Voltage\u003c\/th\u003e\n\u003ctd\u003eDC 28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDigital Outputs\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChannels\u003c\/th\u003e\n\u003ctd\u003e2 switched voltage outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOn State Voltage\u003c\/th\u003e\n\u003ctd\u003eFollows the applied RTU supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput Type\u003c\/th\u003e\n\u003ctd\u003eVoltage outputs, not voltage-free relay contacts or analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent Limit\u003c\/th\u003e\n\u003ctd\u003eMaximum specified output current: 1 A. Contact YenGear for per-channel and combined load limits before connecting two loads.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Sizing\u003c\/th\u003e\n\u003ctd\u003eUse a 2 A adapter when the connected output load exceeds 200 mA; budget combined loads and starting current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAnalog Inputs\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage Input\u003c\/th\u003e\n\u003ctd\u003e1 fixed AV terminal, 0–10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent Input\u003c\/th\u003e\n\u003ctd\u003e1 fixed AI terminal, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±0.5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReported Resolution\u003c\/th\u003e\n\u003ctd\u003e0.001 V \/ 0.001 mA; measurement accuracy is ±0.5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog Outputs\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Input\u003c\/th\u003e\n\u003ctd\u003e10.7 V at AV; 22 mA at AI. Normal measurement ranges are 0–10 V and 4–20 mA.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eSerial Interface\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS485\u003c\/th\u003e\n\u003ctd\u003e1 isolated RS485 A\/B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEsd Protection\u003c\/th\u003e\n\u003ctd\u003e15 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBaud Rates\u003c\/th\u003e\n\u003ctd\u003e1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFormat\u003c\/th\u003e\n\u003ctd\u003e8 data bits; 1 or 2 stop bits; none, odd, or even parity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInitial Setting\u003c\/th\u003e\n\u003ctd\u003e9600 bps, 8-N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eScheduled polling and transparent transport, including configured Modbus RTU frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eReporting And Control\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReporting\u003c\/th\u003e\n\u003ctd\u003ePeriodic acquisition, heartbeat, and input\/output state-change reporting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl\u003c\/th\u003e\n\u003ctd\u003eRemote output commands; timed control, pulse output, and local input-to-output rules require compatible firmware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommissioning\u003c\/th\u003e\n\u003ctd\u003eCheck startup state and communication-loss behavior for the installed firmware. A radio acknowledgement does not prove that the connected equipment changed state.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePower Supply\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003eDC 9–28 V; use one supply for parallel power inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference Adapter\u003c\/th\u003e\n\u003ctd\u003eDC 12 V \/ 1 A; larger supply where required by output load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Working Current\u003c\/th\u003e\n\u003ctd\u003e0.5 A for the RTU; budget controlled loads separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAverage Power\u003c\/th\u003e\n\u003ctd\u003e≤0.5 W; load and operating conditions affect total consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-50 to 95 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e5–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e104 × 97.6 × 25.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApproximately 0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eWall or panel surface; follow supplied mounting drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAntenna Connector\u003c\/th\u003e\n\u003ctd\u003eSMA female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDeployment\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGateway Compatibility\u003c\/th\u003e\n\u003ctd\u003eY501-L or Y511-L with matching regional plan and channels, using an external Network Server or optional local NS\/AS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDownlinks\u003c\/th\u003e\n\u003ctd\u003eClass A receives downlinks after an uplink. Class C provides more receive opportunities. Delivery time depends on airtime, server scheduling and regional radio limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePayload\u003c\/th\u003e\n\u003ctd\u003eConfiguration tools, uplink decoders and downlink commands must match the installed firmware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\n\u003cp\u003eConfirm regional plan, DI wiring, DO voltage and combined load, sensor signals, firmware and payload definitions before ordering. The two outputs are switched voltage outputs, not dry relay contacts.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/store.yengear.com\/pages\/contact\"\u003eAsk YenGear to check your configuration\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/docs.yengear.com\/products\/lorawan\/Y503-2220-L-specification.html\"\u003eY503-2220-L Specification Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/docs.yengear.com\/products\/lorawan\/Y503-2220-L-user-manual.html\"\u003eY503-2220-L User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yengear IoT","offers":[{"title":"CN470","offer_id":67632599007474,"sku":null,"price":72.0,"currency_code":"USD","in_stock":true},{"title":"AS923","offer_id":68090384089330,"sku":null,"price":72.0,"currency_code":"USD","in_stock":true},{"title":"AU915","offer_id":68090384122098,"sku":null,"price":72.0,"currency_code":"USD","in_stock":true},{"title":"EU433","offer_id":68090384154866,"sku":null,"price":72.0,"currency_code":"USD","in_stock":true},{"title":"EU868","offer_id":68090384187634,"sku":null,"price":72.0,"currency_code":"USD","in_stock":true},{"title":"US915","offer_id":68090384220402,"sku":null,"price":72.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/5563\/3138\/files\/Y503-222-L-product.png?v=1791080971"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/5563\/3138\/collections\/Y501-L-product.png?v=1793327405","url":"https:\/\/store.yengear.com\/collections\/lorawan-products.oembed","provider":"YenGear Store","version":"1.0","type":"link"}